Phares Model T6 Panel Mount Process Tachometer

T6 Panel Mount Process Tachometer

View or Download PDF: T6 Tachometer Spec Sheet

Part Number Input Voltage Display
T6-A 100-240 VAC, 50 mA 4 Digits with Decimal Point
T6-D 9-36 VDC, 140 mA 4 Digits with Decimal Point
T6-A-E5 100-240 VAC, 50 mA 5 Digits with Decimal Point
T6-D-E5 9-36 VDC, 140 mA 5 Digits with Decimal Point

Quick Quote

Send an email to get a quote or ask a question.

Order online from our featured distributor, Ram Meter.
Telephone: 248-362-0990

Features

  • Process tachometer with programmable relays and LED display
  • Adjustable parameters
  • 3 programmable relays with isolated N.O./N.C. (Form ‘C’) contacts
  • 4-20mA and 0-10V output signals, scalable, proportional to speed
  • 4-20mA loop externally powered or powered via the T6 Tachometer
  • 1 – 5,000 PPR (pulse per revolution), adjustable
  • Universal sensor input, 2 or 3 wire, PNP or NPN for added ease of integration
  • Universal input voltage, AC and DC
  • Measure RPM, Feet/Minute, and more
  • 4 or 5 digit red LED display, 1/2″ high alpha numeric characters
  • Programmable Scaling and Decimal Points

Benefits

  • Isolated relay contacts make integration easy into new or existing systems
  • Suitable for use in wash down areas (IP67)
  • No DIP switches
  • No calibration required
  • Low maintenance technology
  • Extend the lifespan of your equipment
  • Stop conveyor “domino” effect
  • Detect unexpected load increase
  • Reduce belt breaks

T6 Panel Mount Process Tachometer

Overview

The Phares Model T6 Panel Mount Process Tachometer is an economical, easy to use, maintenance free device which utilizes proactive sensing to catch potential issues before they become a problem. Proactive sensing provides a soft landing instead of a hard crash. This prevents broken belts, gears, chains, sprockets, shear pin, and stressed, overheated electric motors. Typical applications include belt conveyors, drag conveyors, bucket elevators, fans, blowers, rock crushers, and pumps.

The T6 Process Tachometer features an LED display, 0-10V and 4-20mA analog output signals, and 3 SPDT programmable relays, giving you real time support for your production line. The power of data visibility dramatically improves your production.

The Phares Model T6 Panel Mount Process Tachometer is particularly useful for accurately detecting under-speed conditions. Knowing the status of a machine or process is critical. Under-speed conditions often signal unexpected increases in load, the cause of which may lead to a critical stop.

The T6 Process Tachometer programmable relay outputs are useful for quickly activating stop circuit(s), alarm horns, and alarm beacons. The consequences of process failure are great. Fast response time lessens the impact of a hard crash. Less repairs, less clean up, faster re-start.

The T6 Tachometer is essential technology which has the power to monitor your operations and catch potential issues before they become an actual problem.

Many devices in your factory can be replaced with easier-to-use, maintenance free versions. The T6 Tachometer is an easy to use, maintenance free device. Use the adjustable parameters to quickly customize the T6 for your specific application. Isolated relay contacts make it easy to integrate into any new or existing system.

The T6 Panel Mount Tachometer uses frequency input to determine the presence of motion or the lack thereof. The relays engage when machine speed reaches the relay set points. The relays remain engaged when machine speed is at or above the set points. When machine speed falls below the set points, the relays drop out, returning to their normal, fail-safe state. Relay set points are adjustable via the T6 Tachometer front panel.

T6 Panel Mount Process Tachometer

Specifications

View or Download PDF: T6 Tachometer Spec Sheet

Certifications:
Conforms to the following standards:
CAN/CSA C22.2 No. 61010-1:2012
UL 61010-1:2012
EN 61010-1:2012
IP67

Input Power:
Part No. T6-A: 100-240 VAC, 50/60 Hz, 50mA
Part No. T6-D: 9-36 VDC/VAC, 50/60 Hz, 140mA – 36V Max.

Fusing:
1/2 A Max., Input Power
3 A Max., Relay Common

Display:
Seven Segment LED, 4 or 5 Digit, with decimal point.
Ranges: 0-99,999, 0-9,999, 0-999.9, 0-99.99, 0-9.999
LED Height: 0.50″
Color: Red

Dimensions:
1.6875″ H x 3.5625″ W x 5.3750″ D
Cutout Dimensions: 1.75″ H x 3.60″ W, +/- 0.025″

Weight:
1 LB.

Accuracy:
+/- 2 Least Significant Digits

Analog Outputs, Scaled:
0-10 Volt
4-20mA

Universal Signal Input:
24VDC, Sinking or Sourcing, NPN or PNP, 2 or 3 Wire
Sensor Input Current: 0.14mA (min.)

Relays:
Quantity of 3, each with 1 N.O./N.C. (Form C) Contact
Contact Rating: 3A @125 VAC

Operating Temperature:
-30°F to 140°F

Enclosure:
Aluminum enclosure, gasketed, with side mounting bars for control panel installation. When properly installed, gasket will provide a NEMA 4 type seal.

Tech Documents

 

Sensor types compatible with the T6 Panel Mount Tachometer:

Related Products
  • Activates via magnetic north or south pole
  • Available for high temperature environments
  • Recommended for slow applications
  • Available in delrin for corrosive environments
  • Openings match the threads on our sensors (½” inch NPT)
  • Cast aluminum box with gasketed cover (IP67)